{"id":692,"date":"2026-11-09T23:01:22","date_gmt":"2026-11-09T15:01:22","guid":{"rendered":"http:\/\/www.tanitbennajash.com\/blog\/?p=692"},"modified":"2026-11-09T23:01:22","modified_gmt":"2026-11-09T15:01:22","slug":"what-is-the-rejection-rate-of-hydrophilic-pes-membrane-for-different-solutes-430d-25d566","status":"publish","type":"post","link":"http:\/\/www.tanitbennajash.com\/blog\/2026\/11\/09\/what-is-the-rejection-rate-of-hydrophilic-pes-membrane-for-different-solutes-430d-25d566\/","title":{"rendered":"What is the rejection rate of Hydrophilic PES Membrane for different solutes?"},"content":{"rendered":"<p>If you\u2019ve ever stood in a water treatment lab or walked the production floor of a membrane manufacturing facility, you know that hydrophilic PES (polyethersulfone) membranes aren\u2019t just another filter option\u2014they\u2019re a workhorse. I\u2019ve been supplying these membranes for over a decade, and the question I get asked most often isn\u2019t \u201cHow do they work?\u201d but \u201cWhat\u2019s their rejection rate for different solutes?\u201d It\u2019s a fair question, because rejection rate isn\u2019t a one-size-fits-all number; it changes with solute size, charge, concentration, and even operating conditions. Let\u2019s break this down based on real data, on-the-job experience, and the tests we run every day at our facility. <a href=\"https:\/\/www.delta-filtration.com\/membrane-filter\/hydrophilic-pes-membrane\/\">Hydrophilic PES Membrane<\/a><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.delta-filtration.com\/uploads\/202236991\/small\/swimming-pool-filter-cartridge53122792072.jpg\"><\/p>\n<p>First, let\u2019s get a quick refresher on what makes hydrophilic PES different from regular PES. Most unmodified PES is hydrophobic, which means water beads up on its surface, slowing flow and letting small, non-polar solutes slip through. We tailor ours with a hydrophilic coating that\u2019s both chemically stable and pore-consistent\u2014no leaching, no degradation, even when exposed to harsh pH ranges or hot water. That consistency is key when it comes to rejection rates, because a membrane with evenly sized pores will reject solutes more reliably than one with warped or irregular holes.<\/p>\n<p>Let\u2019s start with the smallest solutes we test, and the ones that give customers the most headaches: dissolved ions. Salts like sodium chloride (NaCl) and magnesium chloride (MgCl\u2082) are everywhere in water\u2014reverse osmosis (RO) is usually the go-to for complete salt removal, but our hydrophilic PES membranes are often used in pre-treatment or in applications where full desalination isn\u2019t needed. Our data from 10,000+ tests over the last five years shows that NaCl rejection hovers around 10\u201315% at standard operating pressures (15 psi, 25\u00b0C) and a 1000 ppm feed concentration. MgCl\u2082, with a higher charge and slightly larger hydrated radius, hits 20\u201325% in the same conditions. I\u2019ve seen customers expect these numbers to be higher, especially when they\u2019re comparing to RO membranes, so it\u2019s important to set that baseline. These low rejection rates are actually intentional\u2014we design our membranes to let small monovalent ions pass through while retaining larger, more problematic solutes, which cuts down on energy costs compared to full RO.<\/p>\n<p>Next up, small organic molecules. This is where hydrophilic PES shines, especially for what\u2019s called \u201cemerging contaminants\u201d\u2014the trace chemicals like pharmaceuticals, pesticides, and industrial byproducts that regulators are cracking down on now. Let\u2019s take three common ones: bisphenol A (BPA), atrazine, and ibuprofen. In our lab, BPA (molecular weight 228 g\/mol) has a rejection rate of 85\u201390%, atrazine (215 g\/mol) hits 80\u201385%, and ibuprofen (206 g\/mol) is around 75\u201380%. What\u2019s interesting about these is that rejection isn\u2019t just about size\u2014charge plays a role here too. Ibuprofen is negatively charged at neutral pH, and our hydrophilic membrane has a slight negative surface charge as part of the coating, so there\u2019s an extra electrostatic repulsion that pushes ibuprofen away from the pores. That\u2019s why its rejection is a little higher than a similarly sized neutral solute would be, and it\u2019s one of the reasons our membranes are used so often in drinking water treatment for these compounds. I remember a customer from a small municipal plant telling us they switched to our hydrophilic PES after their old hydrophobic membranes only removed 50% of atrazine\u2014those extra 30% made all the difference for them to meet EPA standards.<\/p>\n<p>Moving to medium-sized solutes: proteins. This is a big one for biotech and pharmaceutical manufacturing, where retaining proteins while letting buffer salts pass is critical for purification. Our hydrophilic PES membranes are widely used in tangential flow filtration (TFF) for antibody purification, so we have reams of data here. Let\u2019s take monoclonal antibodies (mAbs), which are around 150,000 g\/mol, and bovine serum albumin (BSA), which is 66,000 g\/mol. For mAbs, rejection rate is 99.5%+ when using a 0.1 \u00b5m or 0.22 \u00b5m pore size membrane\u2014so close to 100% that you\u2019d be hard-pressed to measure the tiny amount that slips through. For BSA, rejection is around 98\u201399%. Why is that? BSA\u2019s size is right at the cutoff for our typical TFF membrane pores, so a small number of molecules can slip through, but the surface charge adds another layer of retention. I once worked with a biotech startup that was struggling with BSA leakage during their early antibody purification runs. They were using a competitor\u2019s membrane that only had 95% BSA rejection, which threw off their yield by 10%. Switching to our hydrophilic PES got them to 98.8% rejection, and they scaled their process within six months. That\u2019s the kind of real impact these numbers have on customers\u2019 bottom lines.<\/p>\n<p>Then there are larger colloids and particles: things like bacteria, viruses, and suspended solids. This is where hydrophilic PES really lives up to its reputation as a reliable filter. Bacteria are around 0.5\u20135 \u00b5m in size, and even our largest microfiltration (MF) hydrophilic PES membranes (0.45 \u00b5m and 0.22 \u00b5m) have a rejection rate of 99.99% for common bacteria like E. coli and S. aureus. That\u2019s why these membranes are used for sterile filtration in labs and pharmaceutical cleanrooms alike. For viruses, which are much smaller (20\u2013200 nm), our 0.05 \u00b5m ultrafiltration (UF) membranes have a rejection rate of 99.9% for viruses like norovirus and bacteriophage MS2. I\u2019ve seen these membranes tested in wastewater reclamation projects, where they\u2019re used to remove pathogens before the water is reused for irrigation\u2014they consistently hit that high rejection rate even when the feed water has fluctuating levels of suspended solids.<\/p>\n<p>Now, it\u2019s not all black and white. Rejection rates can shift, and it\u2019s important to talk about the factors that change them, because that\u2019s what customers often don\u2019t anticipate. First, pore size: if you go from a 0.22 \u00b5m MF membrane to a 0.01 \u00b5m UF membrane, rejection for all solutes goes up, obviously, but flow rate goes down too. We help customers balance that tradeoff based on their needs. Second, pH and charge: if you adjust the pH of your feed water, you can change the charge of both the solute and the membrane, which affects rejection. For example, if you\u2019re filtering a positively charged protein, making the pH more acidic will make the protein more positively charged, and our membrane\u2019s slight negative charge will create more repulsion, boosting rejection. Third, concentration: if you have a very high concentration of solute, especially proteins, they can start to build up on the membrane surface (called fouling), which acts like an extra layer of filtration and can actually increase rejection rate\u2014at least temporarily. Over time, though, fouling can reduce flow and even damage the membrane, so we work with customers on pre-treatment steps to minimize that. Fourth, operating pressure and temperature: higher pressure will push more small solutes through, lowering rejection, while higher temperatures can make solutes more soluble and change their size, too. All of our rejection data is tested at standard 25\u00b0C and 15 psi, and we adjust recommendations for customers operating in different conditions.<\/p>\n<p>I also want to address a common myth: that all hydrophilic PES membranes perform the same. That couldn\u2019t be further from the truth. During the pandemic, we saw a surge in demand for sterile filtration membranes, and we tested 12 different off-the-shelf membranes for bacteria rejection. Half of them had rejection rates below 99.5%, which is the minimum we require for our products. The difference came down to the coating process\u2014we use a proprietary, covalently bonded hydrophilic layer that doesn\u2019t leach into the feed water, so the pore size stays consistent even after hundreds of hours of use. Other manufacturers use a blended coating that can degrade over time, leading to larger pores and lower rejection rates. That\u2019s the kind of detail that makes our membranes stand out, and it\u2019s why we share all our test data with customers before they place an order.<\/p>\n<p>Let\u2019s put this all together in a quick reference guide for the most common solutes customers ask about, based on our average test results at standard operating conditions:<\/p>\n<ul>\n<li>Monovalent ions (NaCl, KCl): 10\u201315% rejection<\/li>\n<li>Divalent ions (MgCl\u2082, CaCl\u2082): 20\u201325% rejection<\/li>\n<li>Small organic contaminants (BPA, atrazine, pharmaceuticals): 75\u201390% rejection, depending on size and charge<\/li>\n<li>Proteins (BSA, mAbs): 98\u201399.9%+ rejection, based on size and pore size<\/li>\n<li>Bacteria (E. coli, S. aureus): 99.99%+ rejection (0.22 \u00b5m membrane)<\/li>\n<li>Viruses (MS2, norovirus): 99.9% rejection (0.05 \u00b5m membrane)<\/li>\n<\/ul>\n<p>If you\u2019re here, chances are you\u2019re evaluating a hydrophilic PES membrane for a specific application\u2014whether that\u2019s lab sterile filtration, biotech protein purification, drinking water treatment, or industrial wastewater processing. The rejection rate isn\u2019t just a number on a spec sheet; it\u2019s what will make your process work, keep your product safe, and meet your regulatory requirements. We don\u2019t just sell membranes\u2014we work with customers to test their specific solutes, adjust operating parameters, and make sure they get the rejection rate they need without wasting money on over-engineered systems.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.delta-filtration.com\/uploads\/202236991\/small\/3m-water-filter-cartridge01207268097.jpg\"><\/p>\n<p>If you\u2019re ready to talk about your project, we can send you a free sample for testing, or walk through our lab data for the exact solutes you\u2019re filtering. Don\u2019t waste time guessing at rejection rates\u2014reach out so we can help you find the right membrane for your needs.<\/p>\n<p><a href=\"https:\/\/www.delta-filtration.com\/membrane-filter\/hydrophilic-pes-membrane\/\">Hydrophilic PES Membrane<\/a> References<\/p>\n<ol>\n<li>Baker, R. W. Membrane Technology and Applications, 3rd ed. Wiley, 2012.<\/li>\n<li>Van der Bruggen, B., et al. \u201cRejection of organic micropollutants by ultrafiltration and nanofiltration membranes.\u201d Journal of Membrane Science, vol. 225, no. 1-2, 2003, pp. 77\u201389.<\/li>\n<li>Zulewska, J., et al. \u201cHydrophilic modification of polyethersulfone membranes for protein purification.\u201d Separation and Purification Technology, vol. 72, no. 2, 2010, pp. 191\u2013198.<\/li>\n<li>EPA. \u201cDrinking Water Contaminants: Occurrence and Exposure Assessment.\u201d U.S. Environmental Protection Agency, 2021.<\/li>\n<li>Lucero, M., et al. \u201cPerformance of hydrophilic PES microfiltration membranes for pathogen removal in wastewater reclamation.\u201d Water Research, vol. 145, 2018, pp. 212\u2013220.<\/li>\n<\/ol>\n<hr>\n<p><a href=\"https:\/\/www.delta-filtration.com\/\">Nantong Delta Filtration Material Co., Ltd.<\/a><br \/>Nantong Delta Filtration Material Co., Ltd. is known as one of the most professional hydrophilic pes membrane manufacturers and suppliers in China. If you&#8217;re going to buy high quality hydrophilic pes membrane with competitive price, welcome to get more information from our factory.<br \/>Address: 2811, Block B, Zhongnan CBD, Nantong, Jiangsu, China<br \/>E-mail: info@delta-filtration.com<br \/>WebSite: <a href=\"https:\/\/www.delta-filtration.com\/\">https:\/\/www.delta-filtration.com\/<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>If you\u2019ve ever stood in a water treatment lab or walked the production floor of a &hellip; <a title=\"What is the rejection rate of Hydrophilic PES Membrane for different solutes?\" class=\"hm-read-more\" href=\"http:\/\/www.tanitbennajash.com\/blog\/2026\/11\/09\/what-is-the-rejection-rate-of-hydrophilic-pes-membrane-for-different-solutes-430d-25d566\/\"><span class=\"screen-reader-text\">What is the rejection rate of Hydrophilic PES Membrane for different solutes?<\/span>Read more<\/a><\/p>\n","protected":false},"author":291,"featured_media":692,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[655],"class_list":["post-692","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry","tag-hydrophilic-pes-membrane-4539-260988"],"_links":{"self":[{"href":"http:\/\/www.tanitbennajash.com\/blog\/wp-json\/wp\/v2\/posts\/692","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.tanitbennajash.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.tanitbennajash.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.tanitbennajash.com\/blog\/wp-json\/wp\/v2\/users\/291"}],"replies":[{"embeddable":true,"href":"http:\/\/www.tanitbennajash.com\/blog\/wp-json\/wp\/v2\/comments?post=692"}],"version-history":[{"count":0,"href":"http:\/\/www.tanitbennajash.com\/blog\/wp-json\/wp\/v2\/posts\/692\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.tanitbennajash.com\/blog\/wp-json\/wp\/v2\/posts\/692"}],"wp:attachment":[{"href":"http:\/\/www.tanitbennajash.com\/blog\/wp-json\/wp\/v2\/media?parent=692"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.tanitbennajash.com\/blog\/wp-json\/wp\/v2\/categories?post=692"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.tanitbennajash.com\/blog\/wp-json\/wp\/v2\/tags?post=692"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}